How it works

How StylusScope works

Your cartridge is already a precision transducer. StylusScope takes the same signal your amplifier receives, digitises it with a 24-bit converter and analyses it with its own FFT engine. There is no microphone, no room and no computer in the loop.

Measuring

It stays in your system

Connected once, counting for ever

StylusScope sits between your phono stage and your amplifier. The music passes straight through its parallel PASS-THR. sockets, whether it is switched on or not: it listens, it does not process. In standby the screen is dark and the odometer counts every minute a record plays, saving the total every ten minutes. Hours counted this way are measured, not guessed, and the wear log records the difference.

Connections
Connection

The baseline

One reference, taken when the stylus is new

When your setup is final, ideally within the first few playing hours, you play the 5 kHz wear track of the StylusScope Test Record and store the reading as the baseline. It records the output level and the distortion of each channel, and the hours at which it was taken. Every later check is compared with it.

The wear check

Two minutes, every 50 hours

Every 50 playing hours the light turns orange. Clean the stylus, play the same track, press two buttons. The screen shows how much the output level and the distortion of each channel have changed since the baseline, and the result goes into the wear log automatically.

A safeguard refuses any reading whose level is more than 6 dB from the baseline: no stylus loses that much, so it can only be the wrong track or a changed system.

Stylus wear
Wear history

Your own curve

A graph that does not flatter

The Wear History graph plots every check against playing hours, exactly as measured, without smoothing. A trend line appears only when there are at least five checks after the run-in and the slope is at least twice its own statistical uncertainty. Until then the screen says there is no clear trend yet, because that is the true answer.

A new stylus polishes itself in over its first 50 hours or so, and its distortion often falls by 10 to 20 %. The graph marks that period, so a falling line at the start reads as what it is.

Everything it measures

Six functions, one record

F1 Stylus Odometer Playing hours, counted automatically
F2 Stylus Wear Change in level and distortion since the baseline, logged
F3 Azimuth Adjustment Crosstalk and distortion balance between the channels
F4 IMD Measurement Intermodulation distortion of two tones played together
F5 Frequency Response Level of each test frequency relative to 1 kHz
F6 FFT Analyser The whole spectrum in real time, with a reference trace to compare

No computer, no soundcard, no software, no calibration ritual. Two buttons on the top panel, a remote control for the analyser, and a USB stick for firmware updates and data export.

Next

The measurements from one Audio-Technica VM95C, from new to past 1000 playing hours.

See what 1000 hours did to one stylus